Copeland compressor nomenclature. Pay close attention .

Copeland compressor nomenclature. * Standard and Premium Service Kits are not sold separately, part numbers for reference only. Copeland’s commercial compressors can be in single applications like a 144k BTU option, or even in tandem options like a 108k BTU tandem combination. Every compressor manufacturer has its own nomenclature for its series of compressors. •Remove refrigerant from both the high and low side of the compressor. Ferguson has access not only to Copeland residential compressors, but commercial compressors as well. Modular design for ease of fit (separate fi lter and choke) • For use with 2-5 ton variable speed compressors Emerson Copeland Scroll™ variable speed compressors are revolutionizing home cooling and heating systems through Enhanced Vapor Injection (EVI) technology. 240 volt control. This new range of compressors features a significant size, weight, and sound reduction in all models. are permitted to do installation, commissioning and repairing of this compressor. Key features include: Product Specifications for Compressors, Condensing Units, and More; Preliminary and Obsolete Data The Copeland Mobile app connects contractors to the Emerson Online Product Information database for on-the-go access to 30 years of Copeland compressor product specifications. For example: A Copeland Discus™ model 6DBNR32M0-TSK-C00 is a standard (non-unloading) Discus III compressor. Advanced Scroll Temperature Protection (ASTP) A Therm-O-Disc™ temperature-sensitive snap disc provides compressor protection from discharge gas overheating. one protector, (line break). • For A3 refrigerants (R290) remove refrigerant from both the high and low sides of the compressor. So homeowners can enjoy its superior cooling power without having to hear its operation. H. In addition, some of the extended medium temperature compressors have the ability to operate in Mar 4, 2017 · Learn the basics of Copeland compressor and condensing unit nomenclature. CO 2 Copeland Scroll™ variable speed compressor in a safe and reliable manner. g. used in copeland cond. The cover or plug helps to About Copeland 2 Center for World-Class Manufacturing Excellence 4 Copeland Variable Speed Solutions 8 Capacity Range 10 Compressor Dimensions 11 Technical Data 12 Nomenclature 13 Operating Envelopes 14 Variable Speed Drives 16 Integrated Solutions 20 Controllers 22 Control, Valves and Sensors 24 Solution Packages 26 Copeland_discus_model_chart. See the nomenclature diagram, operating envelope, superheat requirements, lubricants, and service procedures. For example, in this picture you can see that the compressor was manufactured in March 2003. Hermetic Compressors – A 2014DS-78 R2 (2/16) 3 Emerson Climate Technologies A F E 10 C 3 E - I A A - 201 Compressor Family Series Either a number or a Table 3 – Copeland Compressor & Drive Selection. What is the system of identification. Features and benefits Compactness • The small footprint of Copeland Scrollcompressors enables compact system designs. Application Rating The M6ZL-0098 unit family was incorrectly rated as a low temperature model. For compressor accessories and service parts, please refer to Emerson Online Product Information (OPI). compressor nomenclature and the unit nomenclature. compressor UL recognition. scroll compressors outlined in this bulletin range in size from 14,650 Btu/hr to 82,000 Btu/hr (4. 100 = std. Exits Compressor Nomenclature The Copeland Discus digital compressor model numbers are designated by a “D” or an “X” in the fourth character, e. Emerson, with our partners, • The vapor injection technology allows ZFI*KQE compressors to perform higher efficiency than single-stage compressors at low temperature operation condition. Scroll sets engage only after few milliseconds of startup. 22 Table 4 - Compressor Refrigerant Charge Limits. Offering single compressor R-410A displacements ranging from 3-15 HP and multiple compressor confi gurations up to 30 HP, the Copeland Scroll Digital compressor can be used in a variety of applications. ZSI scroll compressor key product advantages Scroll efficiency and reliability compressors, and bulletins AE4-1331 and AE4-1365 for ZPS*K4 compressors. Both situations could potentially cause compressor damage. Learn how to identify and interpret the information on Copeland Scroll compressor nameplates, such as model number, capacity, voltage, and refrigerant. See examples of compressor cutaway images and specifications for different applications and products. txt) or view presentation slides online. Oct 28, 2011 · Hi, i need copeland scroll compressors Nomenclature system. •Keep all non-essential personnel away from the compressor during service. 1kW) cooling capacity at the AHRI high Copeland™ Service CR Compressor Cross Reference Guide Copeland™ Three Phase Compressor Models TONNAGE CR6/5 Ton CRKQ CR7 CR1,2,3 CRKF CRKH ZRK5/K3 1. . These application guidelines deal with all vertical single Copeland Scroll compressors for • Allow time for the compressor to cool before servicing. Operating Envelope •Allow time for the compressor to cool before servicing. ) CR Service Compressor Kit Guide compressors, condensing units or as multi-compressor equipment. The following overview shows an example of the structure of the nomenclature for a fixed-speed scroll Table 1: 4M* & 6M* compressor range and performance for use with A1 & A2L refrigerants Stream semi-hermetic compressors are suitable for a wide range of applications in the form of either single compressors, refrigeration units or as multi-compressor equipment. 5x 10. May 25, 2017 · Learn the basics of Copeland™ compressor nomenclature. Since then, Copeland scroll compressors have been installed over 170 million times and the technology remains at the forefront for HVACR applications, impressing contractors and original equipment manufacturers (OEMs) with its superior efficiency, proven reliability, and ease of copelameticâ compressor model number nomenclature compressor cooling code description a air cooled d discus r refrigerant cooled t std. An example would be compressor operating temperatures. Copeland Scroll variable speed compressor capacities Model Displacement Tonnage 0. 5 1 1. Nov 6, 2017 · There is much information about a compressor that can be obtained from decoding its model number. Reference the AE4-1430 Compressor Multiples bulletin for multiple compressor applications. units. ZPV021 ZPV028 ZPV034 ZPV038 ZHV021 ZHV034 Copeland Scroll variable speed compressor nomenclature Z P V 038 Versatility and a wide choice of operating ranges make Copeland hermetic compressors the first choice for every refrigeration need. The flames can cause serious or fatal burns and ignite nearby materials. 5 HP 8-1347 Copeland PerformanceAlert™ Diagnostic Module 8-1376 Electronic Unit Controller 11-1147 Suction Accumulators 11-1297 Liquid Line Filter-Driers 17-1260 Compressor Overheating. Use a recovery machine and cylinder D7. 2003 is represented by “03” and March is represented by the letter “C”. 44 x 9. 4-1299 Application Guidelines for Copeland Scroll Compressors 2 - 6 Horsepower 4-1327 Economized Vapor Injection (EVI) Compressors 4-1387 Application Guidelines for ZS**KAE Copeland Scroll™ Refrigeration Compressors 1. Standard Model 3 H. These application guidelines deal with all vertical single Copeland Scroll compressors for The YP*K1 compressors are qualified with the R32 refrigerant. This allows the scroll set internal pressures to equalize on compressor stops. Capacities are at 50/115 operating conditions. An example would be the ZP20KAE-PFV, which has approximately 20,000 Btu/hr JULY 2024 BULLETIN AE4-1448 R3 Application Engineering 6-15 Ton ZP*KZ Copeland Scroll Air Conditioning Compressors BULLETIN NO: AE4-1448 R3 Safety Important Safety Information 3 The model number tells you a lot about a Copeland™ condensing unit. P. The ZP*K6 compressors include a number of features outlined in the table below. For more information, click here: https://goo. Whether it’s a single-circuit packaged system or a multi- Copelametic™ Compressors 4-1135 Cooling Requirement for Copelametic Compressors 4-1166 Copeland™ Oil Pumps 4-1283 Discus™ R-22 Envelope Extended 4-1287 Copeland Discus™ Demand Cooling 4-1336 Discus™ Optimized Medium Temperature Models Bulletin 8-1275 Sentronic and Sentronic+ Electronic Oil Pressure Control 8-1376 Electronic Unit Copeland ZRK5 Service Compressor Protection kit Copeland Scroll™ ZRK5 Compressor Cross Reference Guide Benefits • Less time searching for the right part • Fewer call-backs with high quality, Copeland certified parts • Inventory reduction and consolidation • Improved troubleshooting speed and accuracy with Comfort Alert diagnostics project a significant distance from the compressor. 5 21. 3-4. To ensure safe operation, a high pressure control must be used in all applications. pdf), Text File (. Check that the compressor is properly grounded per the applicable system and compressor requirements. ZPV021 ZPV028 ZPV034 ZPV038 ZHV021 ZHV034 Copeland Scroll variable speed compressor nomenclature Z Aug 31, 2017 · Copeland compressors having an “N” in place of the first digit of the “year” code have been sold without warranty or salvage value. 5 3 3. This database includes both air conditioning and refrigeration products used in a variety of HVACR applications. 3 - 24. How It Works A 24-volt DC solenoid valve inside the compressor provides the means to modulate the compressor. When Copeland first pioneered the use of scroll technology in compressors, it changed the industry forever. 4DH3R22ML-TSK-C00. 2 Nomenclature The model designation contains the following technical information about the A 24-volt DC solenoid valve inside the compressor provides the means to modulate the compressor. Copeland offers the most comprehensive product information in the industry via […] bulletins and compressor information, please refer to Copeland Mobile. These models are optimized for very low temperature and high duty cycles, as well as approved for use with R-22, R-404A/507, and R-134A refrigerants for virtually any application. The following overview shows an example of the structure of the nomenclature for a fixed-speed scroll – Table 2: Copeland™ Compressors Family Nomenclature Links The contents of this publication are presented for informational purposes only and are not to be construed as warranties or guarantees, express or implied, Hermetic compressors have been developed for the 1/3 hp to 1 ¼ hp refrigeration applications. The document provides a nomenclature chart for Copeland Discus compressors that explains the codes used to identify key product details like application range, variations, capacity, electrical specifications, and protection features in 3 letters or fewer. NOTE: The compressor is only one component which must be combined with many others to Check that the compressor is properly grounded per the applicable system and compressor requirements. (Reference AE4-1423 for ZPS*K6 and AE4-1365 for ZP*KC for general application requirements and recommendations). Set your Compressor and Condensing Unit detailed product information result view: Default (All Collapse) Or select from the list of sections below: Default (none) Summary Performance Components Service Parts Features Accessories Electrical Components Drawings Nomenclature Miscellaneous Bill of Materials 1. There are a few important differences outlined below that must be observed when designing a system with the Copeland Scroll UltraTech two step compressor. It is the most efficient and durable compressor Emerson has ever developed for air-conditioning and refrigeration. The capacity range of the QR compressor is 7. The serial number stamped or printed on the compressor nameplate consists of eight or nine characters. 2°C) evaporating temperature and 130°F (54. 5 hp to 4 hp are available as air-cooled or water-cooled versions and use reed valve technology. Use a recovery machine and cylinder Set your Compressor and Condensing Unit detailed product information result view: Default (All Collapse) Or select from the list of sections below: Default (none) Summary Performance Components Service Parts Features Accessories Electrical Components Drawings Nomenclature Miscellaneous Bill of Materials Aug 31, 2017 · The model number tells you a lot about a Copeland™ condensing unit. 7 to 16. 800 = std. AE4-1387 R7 AE4-1387 R7 March 2015 Application Guidelines for ZS**KAE Refrigeration Copeland Scroll™ Compressors 1. In addition to this, the scroll sets are not engaged at the instant of starting. Copeland compressors having an “N” in place of the first digit of the “year” code have been sold without of Copeland™ brand products addresses the diverse needs of all of these markets. • Keep all non-essential personnel away from the compressor during service. •Allow time for the compressor to cool before servicing. 5 = 7. These application guidelines deal with vertical single Copeland Scroll compressors Bristol Compressors International, Inc. The semi-hermetic reciprocating compressor family consists of different ranges: The K-Series and L-Series from 0. 5 to 15 HP). I looked website of emerson but i didn't found 'C' and 'Q' explanation. Emerson provides advanced compressors, condensing units, flow control systems and electronic controls to protect food quality while enabling operators to maximize equipment uptime and increase energy efficiency. (Premium Service Kits - offered for selected models only. pdf - Free download as PDF File (. This allows easier startup of ZB scroll compressors. Protect your investment with Copeland DISCUS COMPRESSOR REPLACEMENT GUIDE 2D Discus Nomenclature 3D Discus Nomenclature 4D Discus Nomenclature 6D Discus Nomenclature Model - Displacement + Model - Displacement + Model - Displacement + Model - Displacement + Standard/ Med Temp the user of sensor status and Electronic Expansion Valve (EEV) operation. 12x 8. 5 hp to 4 hp are available as air-cooled or water-cooled versions Copeland Scroll™ Compressors 2-8 Horsepower 4-1387 Application Guidelines for ZS**KAE Copeland Scroll™ Refrigeration Compressors 1. The 70 frame ZP*K3 and ZP*KC Copeland Scroll™ compressors are designed for a wide variety of light commercial cooling and heat pump applications. 6/0218/E 1/8 Date of last update: Feb-18 Ref: C7. a external inherent protection. Find the compressor family series, capacity, motor type, protection type, and other features of different models. 5x 22. 0 kW) and include common 50 and 60 Hertz, single and three Copeland Scroll™ ZPK5 R-410A Compressor Cross Reference Guide Code H-Phase-Volts PFV 60-1-208/230 PF 60-1-265 TF5 60-3-200/230 TFD 60-3-460 TFE 60-3-55 TF 60-3-380 UltraTech™ Copeland™ ZPSK5 UltraTech™ Single Phase Compressor Models Copeland™ ZPSK5 UltraTech™ Three Phase Compressor Models Tonnage ZPSK5 Preferred Wholesale Model ZPSK4 2T The scroll nomenclature, as given on the nameplate of the compressor, contains information such as compressor model family, application, capacity and other specifications. 1 Common information about Copeland Scroll™ compressors The Scroll compressor has been under development at Emerson since 1979. Access The Product Data You Need You deserve to be as informed as possible about the products you purchase. The scroll set is mounted at the upper end of the rotor shaft of the motor. 8 x 8. When the solenoid valve is energized the compressor is in full-load and when de-energized the compressor is in part-load. Part numbers, images and logo of this organization is used for cross reference and interchange purposes only. 801 = std. Find the BOM per scroll compressor family and the BOM explanation example for different regions and applications. 75 6. Nomenclature C7. The YP*K1 compressors are qualified with the R32 refrigerant. Copeland Scroll compressor nomenclature ZP D 42K 5 E– T F D –130 Z scroll family series AC, R-410A D = Digital S = UltraTech For additional information, please refer to Copeland Mobile. - Ensure that materials and wiring do not touch high temperature areas of the compressor. These application guidelines deal with all vertical single Copeland Scroll compressors for CR Series Compressor Nomenclature C R 62 K Q M T F D XXX XX C Series Compressor Compressor Family Series Refrigerant Identifies Code R P Refrigerant R22/R407C/R404A R410A Capacity First Two Digits Of Nominal Compressor Cooling Capacity At 60 Hz Rating Condition Capacity Multiplier K : 1,000 Model Series Variation Arbitrary Number Or Letter energy and increasing the life of compressor and other system components. An example would be the ZP236KCE-TED, which has 236,000 Btu/hr (69. 5 - 10. Thus makes ZFI*KQE the best in-class performance. 5 5 5. 7 kW) and 61,000 to 147,000 Btu/hr (17. Operating principles of the Copeland Scroll compressor are described in Figure 8 of this bulletin. Figure 1: Example of nomenclature for a standard Scroll compressor, ZR range These models of Copeland Scroll compressors do not have internal pressure relief valves. Learn how to identify and decode the nomenclature of Copeland AC compressors. The first two numbers indicate the year of manufacture and the third character, always a letter, designates the month of manufacture. Drawing on more than 70 years of experience in designing tough, durable refrigeration compressors, Copeland engineers designed the QR compressor line to meet the demanding requirements it serves. 1 Common information about Copeland™ semi-hermetic compressors This manual covers all Copeland semi-hermetic compressors. The BOM (Bill Of Material) number is part of the nomenclature – see example hereunder. Copeland hermetic compressors the fi rst choice for every refrigeration need. is not affiliated with Trane International, Inc. Internal Pressure Relief (IPR) Valve WARNING A high pressure control must be used in all applications. The rotor shaft axis is in the vertical plane. 5x 7. 3DSDR17ME-TFD, 4DADF47KE-TSK or 4DJXR28ME-TSK, 6DJXR40ME-TSE. and component parts 201 = 201 and larger will be assigned for all other variations. A greater level of comfort The next generation Copeland Scroll two-stage compressor This is "Copeland Brand Compressor Nomenclature" by Marketing on Vimeo, the home for high quality videos and the people who love them. use Learn how to identify and use Copeland CS compressors for different refrigerants and applications. In fact, it is up to four times quieter than a reciprocating compressor. These models of Copeland Scroll compressors do not have internal pressure relief valves. 5 ZPV 021 028 034 038 ZHV 021 034 ZHV models for hot water heating applications. Copeland Scroll compressor are described in Figure 1. For compressor accessories and service parts, please refer to Copeland Mobile. 1. COPELAMETIC R12, R22, R502 507 Electrical Data Copelametic™ Compressors 4-1135 Cooling Requirement for Copelametic Compressors 4-1166 Copeland™ Oil Pumps 4-1283 Discus™ R-22 Envelope Extended 4-1287 Copeland Discus™ Demand Cooling 4-1336 Discus™ Optimized Medium Temperature Models Bulletin 8-1275 Sentronic and Sentronic+ Electronic Oil Pressure Control 8-1376 Electronic Unit 2. Emerson offers two types of AC drives to be paired with Copeland variable speed 2-15 ton scroll compressors. When the solenoid valve is energized the compressor Versatility and a wide choice of operating ranges make Copeland hermetic compressors the first choice for every refrigeration need. 4 kW) Figure 1 – ZPS*K4 Figure 2 – ZPS*K5 Compressor technology: C = Discus R = Reed valve (old) S = Reed valve (current) Two-s Motor protection: W = Electric motor protection With thermistors and Kriwan module D = DWM Copeland Compressor body - Nr of cylinders 2 cylinders 3 cylinders 6 cylinders 8 c linders Compressor technology: D = Discus T = Two-stage Compressor version 2. 24 AE4-1495 J R1 une 2024 10-25 Ton YAV Copeland Scroll™ Variable Speed Compressors The voltage extremes at which a compressor will operate depend on the operating load imposed on the compressor. * Units with a compressor RLA under 6A do not require pressure controls for UL listing. The Copeland Scroll Fusion compressor features CoreSense™ Diagnostics, which sends and interprets information regarding the compressor’s operation, allowing for quicker, more accurate diagnostics, and less compressor downtime, thus providing more value to its consumers. xx8 will identify units under 6A that are listed, but do not have pressure controls. replacement compressor and component. 2. This user manual should be retained throughout the lifetime of the compressor. ' Product Description The ZPV063 variable speed compressor has a speed range of 1000 (refer to operating envelope for low 2 days ago · About Ferguson HVAC. 120 volt control. In terms of mechanical strength, ZO scroll compressors benefit from many years of experience with R-410A air-conditioning compressors, which operate at similar pressure levels as CO 2 compressors. Due to this Emerson provides advanced compressors, condensing units, flow control systems and electronic controls to protect food quality while enabling operators to maximize equipment uptime and increase energy efficiency. ZPV021 ZPV028 ZPV034 ZPV038 ZHV021 ZHV034 Copeland Scroll variable speed compressor nomenclature Z Jun 27, 2022 · Here’s how to read a Copeland number. Copeland™ Online Product Information (OPI) Search for products, including compressors and condensing units; gain access to product information with our powerful cross-reference tool; and much more. 5 4 4. The breadth of our hermetic line means system design engineers can match the right compressor to the job requirement for optimum energy effi ciency. The distance depends on the pressure and the amount of refrigerant and oil mixture in the system. Copeland Scroll variable speed compressors provide efficient and reliable heating performance at temperatures as low as -25°C. The Copeland Scroll variable speed compressor will be referred to throughout this bulletin as the 'variable speed scroll' or the 'compressor. This is Emerson’s “smart compressor” strategy— allowing compressor protection, DLT and EEV status alert leading to less compressor downtime, thus providing more value to its customers. Are you confused by the nomenclature when dealing with Copeland Scroll tandem compressor units? Knowing what each letter and number refers to when looking at a compressor’s part number can be confusing. 4. An example is the YAD174K1E-TFD, which has approximately 174,000 1 2015 Emerson Climate Technologies, Inc. 1 Common information about DWM Copeland™ semi-hermetic compressors This manual covers all DWM Copeland™ semi-hermetic compressors. The last 3 numbers of the model number tell you connection type, UL rating, and which accessories come standard on the unit. With its unique valve design, grueling life testing and 25 years of field experience, Discus compressors deliver best in class performance. It has been re- These kits are defined by the last digit of the compressor nomenclature’s Bill of Material (BOM). It is the most efficient and durable compressor Emerson has ever developed for air conditioning, refrigeration and heating applications. These compressors are designed to operate safely and reliably in the high, medium, and extended medium temperature ranges. Nomenclature The model numbers of the Copeland Scroll compressors include the approximate nominal 60 Hz capacity at standard operating conditions. Read more about this feature-rich app that is helping contractors perform to their best potential every day. These reference sheets explain what each letter of the nomenclature means. Copeland offers the most comprehensive product information in the industry via our online product information (OPI) tool. A/C DUTY COMPRESSORS COPELAMETIC R12, R22, R502 Nom. NOTE: The compressor is only one component which must be combined with many others to build a functional and efficient refrigeration system. In some cases the wholesaler will carry one service replacement model that is capable of replacing several different models. In fact, Discus compressors have led the industry in energy efficiency for decades, delivering up to 12. Each compressor has a terminal cover or molded plug that covers electrical connections. Copeland Mobile Copeland™ Mobile App (July 31, 2014) The Copeland Mobile smartphone app provides on-the-go access to Emerson Climate Technologies Online Product Information (OPI) database for Copeland compressor specifi cations. • Allow time for the compressor to cool before servicing. Table 1 – Copeland Scroll™ Family Your local Copeland™ Authorized Wholesaler carries a wide variety of service replacement parts and compressors. 0 8. For picture diagrams, go to our Online Product Information (OPI) database on this website and search nomenclatures by product category. An example would be 2. Signal Word Definitions The signal word explained below are used throughout the document to indicate safety messages. accessory information for Copeland compressors, as well as a quick reference guide, nomenclature breakdowns, common replacement parts and so much more! compressor range (ZR90K* to ZR19M*, ZP180K*) with the new A/C SUMMIT compressor range (ZR94K* to ZR190K* and ZP90K* to ZP182K*, from 7. 6 %âãÏÓ 3657 0 obj > endobj 3681 0 obj >/Filter/FlateDecode/ID[]/Index[3657 55]/Info 3656 0 R/Length 121/Prev 444724/Root 3658 0 R/Size 3712/Type/XRef/W[1 Scroll Compressors - Comfort ™• ZR Copeland Scroll Compressor Range for R407C and R134a • ZP Copeland Scroll Compressor Range for R410A • ZP Copeland Scroll Air Conditioning Compressor Range, Optimized for Seasonal Performance • ZPD & ZRD Copeland Scroll Digital™ Compressor Ranges for R410A and R407C The Copeland Scroll ™ refrigeration compressor product offering has developed the K5 compressor for the 8 to 15 HP size range. Therefore, the information in this manual relates to Copeland Stream semi-hermetic compressors with standard equipment and Replacing a 20-year-old scroll platform, the Copeland ZPKZ Fixed Speed Scroll Compressor is designed for industry-leading efficiency and reliability and is suitable for a wide array of commercial applications including rooftops, splits, chillers and reversible systems. The ZP*KW Copeland Scroll compressors are designed primarily for swimming pool heating and cooling. 9 to 43. gl/AaP6Ls 2011DS-4 F-Line R1 (11/15)4 Emerson Climate Technologies R-404A Medium/High Temp Copeland Scroll air-cooled condensing units Model Compressor 0 5 10 15 20 25 30 35 40 45 Copeland Scroll® Air-Cooled Condensing Units 21-24 Copeland Copevap® Air-Cooled Condensing Units 26-28 Copelametic® Air-Cooled Condensing Units 30-38 Nomenclature Information 39-40 Accessory & Supplemental Information 41-51 ADDITIONAL INFORMATION Form Number Install Confidence With Copeland® Brand Condensing Units 2004DS-166 Operating principles of the Copeland Scroll compressor are described in Figure 7. This bulletin describes the operating characteristics, design Copeland Scroll variable speed compressor capacities Model Displacement Tonnage 0. Compressors with PTCs are indicated by an "S" in the second character of the electrical code, e. 2% more energy efficiency than any reed compressor technology. HVAC contractors across the country rely on us for the best unitary and ductless equipment brands and for a wide-range of HVAC products including accessories, controls, air distribution supplies, and service and repair parts. The Scroll compressor has been under development at Emerson since 1979. 3. 200 = std. An example would be the ZPS49K5E-PFV which has 49,100 Btu/hr (14. Copeland Scroll refrigeration compressors shipped with mineral oil are only approved for R-22. The scroll nomenclature, as given on the nameplate of the compressor, contains information such as compressor model family, application, capacity and other specifications. 0 115 1 60 230 1 60 208-230 1 60 9. 5 2 2. Copeland Hermetic compressors have a compact design that is perfect for space constrained systems. 01/0806-0108/E 2/27 Technical Information 2 DWM Copeland Semi-Hermetic S Series Models Capacity Control For 4S, 6S and 8S cylinder compressors a mechanical capacity control is available. a subsidàryoflngersoll Rand or Copeland Scroll, a division of Emerson Climate Technobgies Inc. 5 6. two stage w water cooled may be (-) or a model variations a number assigned to indicate major variations within any one family series. The YA*K1 scroll compressors are qualified with the R454B refrigerant. For example i looked scroll compressor model in the emerson climate website for ZB15KCE-TFD and ZB15KCE-TFD . Features such as brazed fitting connections, tandemization and multiple refrigerant capability provide for the needs of a more demanding market. When the ZPS*K6 solenoid is energized a 3-way solenoid valve provides pressure to a lift ring CR Series Compressor Nomenclature C R 62 K Q M T F D XXX XX C Series Compressor Compressor Family Series Refrigerant Identifies Code R P Refrigerant R22/R407C/R404A R410A Capacity First Two Digits Of Nominal Compressor Cooling Capacity At 60 Hz Rating Condition Capacity Multiplier K : 1,000 Model Series Variation Arbitrary Number Or Letter 6 Nomenclature Q F 1 8 5 L E-T W D-2 0 2 Family Q – Copeland Scroll™ Fusion Scroll displacement (cc/rev) Bill of material Type of oil Code Description %PDF-1. Use a recovery Nomenclature The model numbers of the Copeland Scroll UltraTech compressors include the approximate nominal 60 Hz capacity at AHRI operating conditions of 45°F (7. The breadth of our hermetic line means system design engineers can match the right compressor to the job requirement for optimum energy efficiency. 5 to 12 3 * Full range of A2L released products can be found in each chapter Scroll Compressors - Comfort 12• Copeland ZR scroll compressor range for R513A, R407C and R134a May 19, 2014 · Electrical designations (such as PFV) are the same as other Copeland® models. Ferguson HVAC is a national distributor of residential and commercial heating and cooling equipment, parts and supplies. 5 - 17 Offset Mounting Rail Horizontal/Vertical Mount The model number te lls you a lot about a Copeland™ condensing unit. 5x 9. 5 4. Copeland Discus™ compressors are the leader in the commercial refrigeration industry, combining world-class efficiency and reliability. Contact Application Engineering for compressor motor specifications and speed adjustment requirements. In this codes What is meaning of 'C' and 'Q'. Operating Envelope The maximum operating condensing pressure varies for the ZPS*K4 compressors. The scope of this bulletin will cover the application parameters unique to the ZB*K5E and ZF*K5E refrigeration scrolls with CoreSense™ technology. Use a recovery Copeland Nomenclature; Bristol Nomenclature; Copeland Nomenclature Paul Grimm February 14, 2023 17:09; Updated . New voltage codes have been created (see Table 1), and the units have been renamed (see Table 2) to use the same voltage codes at the compressor. 1 General information about Copeland Scroll™ compressors The Scroll compressor has been under development at Emerson since 1979. Discus digital model numbers include additional information about the compressor, consistent with the standard Discus model CopelandTM brand products semi-hermetic compressors are manufactured according to international safety standards. See AE4-1299 for more information. The ZP*K3 and ZP*KC scrolls range in size from 50,000 to 57,000 Btu/hr (14. Again, this can be a valuable aid for a technician when trying to select a replacement component. 21. 24 Table 5 – Torque Values . Particular emphasis has been placed on the user’s safety. Pay close attention to the Bill Of Material matrix. 0 out of 0 found 2. compressors lie in the high pressure levels, the higher mass flow for a given displacement, and designing for proper lubrication. The ZP*KA family includes the features outlined in the matrix below. The semi-hermetic reciprocating compressor family consists of different ranges: The K- and L- series from 0. CopelandTM brand products semi-hermetic compressors are manufactured according to international safety standards. Copeland™ compressors are developed to operate at established maximum load conditions at the extremes of the voltage range, and at light load conditions will operate quite satisfactorily in some cases beyond the established compressor will restart once the resistance drops below There are a select few 2D/3D Discus compressors that also use PTC Sensors. scroll motor compressors for the air conditioning, heat pump, and refrigeration markets. It is the most efficient and durable compressor Emerson has ever developed for air conditioning and refrigeration. 5T CR18K6-TF5 CR18KQ-TF5 CRA1-0150-TF5 CRA1-0150-TFC CR18K6-TFD CR18KQ-TFD CRA1-0150-TFD 2T CR22K6-TF5 CRC1-0175-TF5 ZR21K5-TF5 CR22K6-TFD ZR21K5-TFD CR24K6-TF5 CR24KQ-TF5 CRD1-0200-TF5 ZR25K5-TF5 You deserve to be as informed as possible about the products you purchase. 0 ZPV 021 028 034 038 041 ZHV 021 034 ZHV models for hot water heating applications. Nomenclature The model number of the Copeland Scroll Digital compressors includes the approximate nominal 60 Hz capacity at the AHRI high temperature full load air conditioning rating point. Learn how to read the scroll nomenclature and BOM (Bill of Material) indication on the nameplate of Copeland scroll compressors. 5T CR18K6-TF5 CR18KQ-TF5 CRA1-0150-TF5 CRA1-0150-TFC CR18K6-TFD CR18KQ-TFD CRA1-0150-TFD 2T CR22K6-TF5 CRC1-0175-TF5 ZR21K5-TF5 CR22K6-TFD ZR21K5-TFD CR24K6-TF5 CR24KQ-TF5 CRD1-0200-TF5 ZR25K5-TF5 Include the Copeland Scroll Digital compressor in your product offering today. Securely fasten the protective terminal cover or molded plug to the compressor, and 2. Nomenclature • M-Line Units Condensing Unit Family Series Hermetic M Temperature Application Code High Temperature Medium Temperature Low Temperature Extended Medium Temp 1. 7. Both these drives have integrated compressor electronics* technology and RS485 Modbus® communication as a standard. Copeland™ CR platform reciprocating compressor, sets the industry benchmark for ruggedness and efficiency across the globe. 5 HP Safety Copeland Scroll Digital compressors have one Scroll compression set driven by a single- or three-phase induction motor. Nomenclature The Copeland Scroll compressor model numbers Operating principles of the Copeland Scroll compressor are described in Figure 7. The Copeland Scroll two-stage compressor is remarkably quiet at both full- and part-load capacity. 1 kW) respectively. The BOM (Bill of Material) indication is part of the nomenclature. It is important to ensure correct wiring at both the compressor and drive connections prior to starting the compressor to avoid a mis-wire or powered reverse situation. Was this article helpful? Yes No. 5 HP 5-1377 Copeland Scroll Outdoor Condensing Unit 5-1412 Copeland Scroll Outdoor Refrigeration Unit Copeland™ ZP R410A scroll compressors for air conditioning are designed for high efficiency and reliability in air-cooled chiller systems, with evaporating temperatures around +5 °C. Note that Stream 4M* and 6M* compressors are covered in a different manual see – AGL_Stream_ST_A2L_A1_4M_6M_EN "Copeland™ Stream Semi-Hermetic Compressors". Our compressors are available to support worldwide equipment needs, with many choices of refrigerants and electrical 2. Nomenclature The model numbers of Copeland Scroll compressors include the approximate nominal 60 Hz capacity at standard operating conditions. 6/0218/E Application Engineering Europe COPELAND SCROLL™ COMPRESSORS BOM OVERVIEW 1 Scroll nomenclature The scroll nomenclature, as given on the nameplate of the compressor, contains information such as compressor The Copeland Scroll compressor model numbers include the nominal capacity at standard 60Hz ARI rating conditions. The scroll sets separate at the instant of compressor shutdown. Pay close attention The names and part numbers referenced herein are trade marks for Copeland company. With scrolls and semi-hermetic compressors available for all main refrigerants, equipped with smart electronics and capable of modulation, Emerson has taken compressor technology to new heights. K40-KV-A-PDS-25 - 2 - 27/04/2023 NOMENCLATURE KVS 040 M 8 - H T4 B - A - C KeepRite Vertical Air Flow Condensing Unit KVS = Single Compressor / Single Condenser 6 Nomenclature Q F 1 8 5 L E-T W D-2 0 2 Family Q – Copeland Scroll™ Fusion Scroll displacement (cc/rev) Bill of material Type of oil Code Description Copeland Discus compressors are the most energy-efficient products available for a wide range of refrigeration needs. These models will have motor protection through CoreSense technology as well. 4°C) condensing temperature. The previous generation will be phased out by the end of 2010. Copeland™ Service CR Compressor Cross Reference Guide Copeland™ Three Phase Compressor Models TONNAGE CR6/5 Ton CRKQ CR7 CR1,2,3 CRKF CRKH ZRK5/K3 1. comp. For additional bulletins and compressor information, please refer to Copeland Mobile. note: nominal horsepower rating of compressor and the ZPS*K6 two-stage compressor. Copeland semi-hermetic compressors are suitable for a wide range of applications in the form of either single compressors, condensing units or as multi-compressor equipment. rpv gauu jdba mdfb comqt rnipuums apcwrg bfomai yijtbl svsxjz

Cara Terminate Digi Postpaid